Documentation

Discrete-Time Signals

Time and Frequency Terminology

Simulink® models can process both discrete-time and continuous-time signals. Models built with DSP System Toolbox™ software are often intended to process discrete-time signals only. A discrete-time signal is a sequence of values that correspond to particular instants in time. The time instants at which the signal is defined are the signal's sample times, and the associated signal values are the signal's samples. Traditionally, a discrete-time signal is considered to be undefined at points in time between the sample times. For a periodically sampled signal, the equal interval between any pair of consecutive sample times is the signal's sample period, Ts. The sample rate, Fs, is the reciprocal of the sample period, or 1/Ts. The sample rate is the number of samples in the signal per second.

The 7.5-second triangle wave segment below has a sample period of 0.5 second, and sample times of 0.0, 0.5, 1.0, 1.5, ...,7.5. The sample rate of the sequence is therefore 1/0.5, or 2 Hz.

A number of different terms are used to describe the characteristics of discrete-time signals found in Simulink models. These terms, which are listed in the following table, are frequently used to describe the way that various blocks operate on sample-based and frame-based signals.

TermSymbolUnitsNotes

Sample period

Ts
Tsi
Tso

Seconds

The time interval between consecutive samples in a sequence, as the input to a block (Tsi) or the output from a block (Tso).

Frame period

Tf
Tfi
Tfo

Seconds

The time interval between consecutive frames in a sequence, as the input to a block (Tfi) or the output from a block (Tfo).

Signal period

T

Seconds

The time elapsed during a single repetition of a periodic signal.

Sample frequency

Fs

Hz (samples per second)

The number of samples per unit time, Fs = 1/Ts.

Frequency

f

Hz (cycles per second)

The number of repetitions per unit time of a periodic signal or signal component, f = 1/T.

Nyquist rate

Hz (cycles per second)

The minimum sample rate that avoids aliasing, usually twice the highest frequency in the signal being sampled.

Nyquist frequency

fnyq

Hz (cycles per second)

Half the Nyquist rate.

Normalized frequency

fn

Two cycles per sample

Frequency (linear) of a periodic signal normalized to half the sample rate, fn = ω/π = 2f/Fs.

Angular frequency

Ω

Radians per second

Frequency of a periodic signal in angular units, Ω = 2πf.

Digital (normalized angular) frequency

ω

Radians per sample

Frequency (angular) of a periodic signal normalized to the sample rate, ω = Ω/Fs = πfn.

    Note   In the Block Parameters dialog boxes, the term sample time is used to refer to the sample period, Ts. For example, the Sample time parameter in the Signal From Workspace block specifies the imported signal's sample period.

Recommended Settings for Discrete-Time Simulations

Simulink allows you to select from several different simulation solver algorithms. You can access these solver algorithms from a Simulink model:

  1. In the Simulink model window, from the Simulation menu, select Model Configuration Parameters. The Configuration Parameters dialog box opens.

  2. In the Select pane, click Solver.

    The selections that you make here determine how discrete-time signals are processed in Simulink. The recommended Solver options settings for signal processing simulations are

    • Type: Fixed-step

    • Solver: Discrete (no continuous states)

    • Fixed step size (fundamental sample time): auto

    • Tasking mode for periodic sample times: SingleTasking

You can automatically set the above solver options for all new models by running the dspstartup.m file. See Configure the Simulink Environment for Signal Processing Models in the DSP System Toolbox Getting Started Guide for more information.

In Fixed-step SingleTasking mode, discrete-time signals differ from the prototype described in Time and Frequency Terminology by remaining defined between sample times. For example, the representation of the discrete-time triangle wave looks like this.

The above signal's value at t=3.112 seconds is the same as the signal's value at t=3 seconds. In Fixed-step SingleTasking mode, a signal's sample times are the instants where the signal is allowed to change values, rather than where the signal is defined. Between the sample times, the signal takes on the value at the previous sample time.

As a result, in Fixed-step SingleTasking mode, Simulink permits cross-rate operations such as the addition of two signals of different rates. This is explained further in Cross-Rate Operations.

Other Settings for Discrete-Time Simulations

It is useful to know how the other solver options available in Simulink affect discrete-time signals. In particular, you should be aware of the properties of discrete-time signals under the following settings:

  • Type: Fixed-step, Mode: MultiTasking

  • Type: Variable-step (the Simulink default solver)

  • Type: Fixed-step, Mode: Auto

When the Fixed-step MultiTasking solver is selected, discrete signals in Simulink are undefined between sample times. Simulink generates an error when operations attempt to reference the undefined region of a signal, as, for example, when signals with different sample rates are added.

When the Variable-step solver is selected, discrete time signals remain defined between sample times, just as in the Fixed-step SingleTasking case described in Recommended Settings for Discrete-Time Simulations. When the Variable-step solver is selected, cross-rate operations are allowed by Simulink.

In the Fixed-step Auto setting, Simulink automatically selects a tasking mode, single-tasking or multitasking, that is best suited to the model. SeeSimulink Tasking Mode for a description of the criteria that Simulink uses to make this decision. For the typical model containing multiple rates, Simulink selects the multitasking mode.

Cross-Rate Operations

When the Fixed-step MultiTasking solver is selected, discrete signals in Simulink are undefined between sample times. Therefore, to perform cross-rate operations like the addition of two signals with different sample rates, you must convert the two signals to a common sample rate. Several blocks in the Signal Operations and Multirate Filters libraries can accomplish this task. See Convert Sample and Frame Rates in Simulink for more information. Rate change can happen implicitly, depending on diagnostic settings. See Multitask rate transition, Single task rate transition. However, this is not recommended. By requiring explicit rate conversions for cross-rate operations in discrete mode, Simulink helps you to identify sample rate conversion issues early in the design process.

When the Variable-step solver or Fixed-step SingleTasking solver is selected, discrete time signals remain defined between sample times. Therefore, if you sample the signal with a rate or phase that is different from the signal's own rate and phase, you will still measure meaningful values:

  1. At the MATLAB® command line, type ex_sum_tut1ex_sum_tut1.

    The Cross-Rate Sum Example model opens. This model sums two signals with different sample periods.

  2. Double-click the upper Signal From Workspace block. The Block Parameters: Signal From Workspace dialog box opens.

  3. Set the Sample time parameter to 1.

    This creates a fast signal, (Ts=1), with sample times 1, 2, 3, ...

  4. Double-click the lower Signal From Workspace block

  5. Set the Sample time parameter to 2.

    This creates a slow signal, (Ts=2), with sample times 1, 3, 5, ...

  6. From the Display menu choose Sample Time > Colors.

    Checking the Colors option allows you to see the different sampling rates in action. For more information about the color coding of the sample times see View Sample Time Information in the Simulink documentation.

  7. Run the model.

      Note   Using the dspstartup configurations with cross-rate operations generates errors even though the Fixed-step SingleTasking solver is selected. This is due to the fact that Single task rate transition is set to error in the Sample Time pane of the Diagnostics section of the Configuration Parameters dialog box.

  8. At the MATLAB command line, type dsp_examples_yout.

    The following output is displayed:

    dsp_examples_yout =
         1     1     2
         2     1     3
         3     2     5
         4     2     6
         5     3     8
         6     3     9
         7     4    11
         8     4    12
         9     5    14
        10     5    15
         0     6     6
    

    The first column of the matrix is the fast signal, (Ts=1). The second column of the matrix is the slow signal (Ts=2). The third column is the sum of the two signals. As expected, the slow signal changes once every 2 seconds, half as often as the fast signal. Nevertheless, the slow signal is defined at every moment because Simulink holds the previous value of the slower signal during time instances that the block doesn't run.

In general, for Variable-step and Fixed-step SingleTasking modes, when you measure the value of a discrete signal between sample times, you are observing the value of the signal at the previous sample time.

Was this topic helpful?