Data Description:
A set of three Li-ion batteries (# 33, 34 and 36) were run through 3 different operational profiles (charge, discharge and impedance) at room temperature (24 deg C). Charging was carried out in a constant current (CC) mode at 1.5A until the battery voltage reached 4.2V and then continued in a constant voltage (CV) mode until the charge current dropped to 20mA. Discharge was carried out at 4A until the battery voltage fell to 2.0V and 2.2V for batteries 33 and 34 respectively. For battery 36 discharge was done at 2A until voltage fell to 2.7V. Impedance measurement was carried out through an electrochemical impedance spectroscopy (EIS) frequency sweep from 0.1Hz to 5kHz. The experiments were carried out until the capacity had reduced to 1.6Ahr (20% fade).

Files:
B0033.mat	Data for Battery #33
B0034.mat	Data for Battery #34
B0036.mat	Data for Battery #36

Data Structure:
cycle:	top level structure array containing the charge, discharge and impedance operations
	type: 	operation  type, can be charge, discharge or impedance
	ambient_temperature:	ambient temperature (degree C)
	time: 	the date and time of the start of the cycle, in MATLAB  date vector format
	data:	data structure containing the measurements
	   for charge the fields are:
		Voltage_measured: 	Battery terminal voltage (Volts)
		Current_measured:	Battery output current (Amps)
		Temperature_measured: 	Battery temperature (degree C)
		Current_charge:		Current measured at charger (Amps)
		Voltage_charge:		Voltage measured at charger (Volts)
		Time:			Time vector for the cycle (secs)
	   for discharge the fields are:
		Voltage_measured: 	Battery terminal voltage (Volts)
		Current_measured:	Battery output current (Amps)
		Temperature_measured: 	Battery temperature (degree C)
		Current_charge:		Current measured at load (Amps)
		Voltage_charge:		Voltage measured at load (Volts)
		Time:			Time vector for the cycle (secs)
		Capacity:		Battery capacity (Ahr) for discharge till 2.7V 
	   for impedance the fields are:
		Sense_current:		Current in sense branch (Amps)
		Battery_current:	Current in battery branch (Amps)
		Current_ratio:		Ratio of the above currents 
		Battery_impedance:	Battery impedance (Ohms) computed from raw data
		Rectified_impedance:	Calibrated and smoothed battery impedance (Ohms) 
		Re:			Estimated electrolyte resistance (Ohms)
		Rct:			Estimated charge transfer resistance (Ohms)