Main Content

Masked zero crossings

Description

Select the diagnostic action to take if Simulink® detects zero-crossings that are being masked.

Category: Diagnostics

Settings

Default: none

none

Simulink software takes no action.

warning

Simulink software displays a warning.

error

Simulink software terminates the simulation and displays an error message.

Tips

This parameter is enabled only if Type is set to Variable-step.

Command-Line Information

Parameter: MaskedZcDiagnostic
Value: 'none' | 'warning' | 'error'
Default: 'none'

Recommended Settings

ApplicationSetting
Debuggingwarning
TraceabilityNo impact
Efficiencynone
Safety precautionNo impact

Related Topics