usb 6008 error message

5 vues (au cours des 30 derniers jours)
mado
mado le 4 Fév 2014
% when i used this daq and i changed the channel id to ai4 up to 7 it gives this error from ai0 to ai3 it works fine
% NI Error -200077:
Requested value is not a supported value for this property. The property value may be
invalid because it conflicts with another property.
Property: DAQmx_AI_Min
Requested Value: -20.0
Valid Values Begin with: -10.0
Valid Values End with: 10.0
%
Channel Name: Dev1/ai4
Task Name: _unnamedTask<44B>
Status Code: -200077

Réponses (1)

Walter Roberson
Walter Roberson le 5 Fév 2014
A patch is given there. The problem was fixed as of R2012b.