Tuning transfer function to get only positive parameters using Simulink

1 vue (au cours des 30 derniers jours)
Ismaeel
Ismaeel le 16 Avr 2017
Modifié(e) : Ismaeel le 18 Avr 2017
I have a transfer function with order three in both numerator and denominator. I am tuning the block using the control system tuner to find the best coefficients for the block for a desired function. My question is how to tell the tuner that the coefficients to be found must be positive values?
ex: tf=(a1*s+1)(a2*s+1)(a3*s+1)/((b1*s+1)(b2*s+1)(b3*s+1))
I want to find the values of the parameters all a & b to be positive values. Any idea? Thanks

Réponses (1)

Sebastian Castro
Sebastian Castro le 17 Avr 2017
For all tuned blocks, you can expand the variable name and set their "Minimum" and "Maximum" values. If you set a minimum of 0, does it work?
Sebastian
  3 commentaires
Ismaeel
Ismaeel le 18 Avr 2017
Modifié(e) : Ismaeel le 18 Avr 2017
Apparently, there is a technical issue to upload the picture. Anyway, this is what I got:
Numerator coefficients:
[-0.17873835660206 -0.241501688056885]
Denominator coefficients:
[1 0.372855801788186]
Ismaeel
Ismaeel le 18 Avr 2017
Modifié(e) : Ismaeel le 18 Avr 2017
I have soled my problem by changing the transfer function to multiple simple blocks (integral, gain, and sum) using the rules from control theory. Thanks Castro.

Connectez-vous pour commenter.