Fangjun Jiang - MATLAB Central
photo

Fangjun Jiang


Last seen: 3 jours il y a Actif depuis 2011

Followers: 3   Following: 0

Message

What is a model? Professional Interests: Model-Based Development

Programming Languages:
MATLAB
Spoken Languages:
English
Pronouns:
He/him

Statistiques

All
MATLAB AnswersCodyFrom 01/11 to 02/25Use left and right arrows to move selectionFrom 01/11Use left and right arrows to move left selectionTo 02/25Use left and right arrows to move right selectionUse TAB to select grip buttons or left and right arrows to change selection100%

RANG
25
of 297 182

RÉPUTATION
10 286

CONTRIBUTIONS
14 Questions
4 062 Réponses

ACCEPTATION DE VOS RÉPONSES
71.43%

VOTES REÇUS
1 555

  • Master
  • 36 Month Streak
  • Revival Level 3
  • First Review
  • Thankful Level 3
  • Knowledgeable Level 5
  • First Answer
  • Solver

Afficher les badges

Feeds

Afficher par

Réponse apportée
I am getting error for configurable subsystem in R2024b
"Configurable subsystem" is in pretty old versions of Simulink. It sounds like that in R2024b, it is definitely no longer suppor...

4 jours il y a | 1

Réponse apportée
How to read out value from simout object
You need to click that signal line, right click, select properties, and then give it a name and log the signal. Once done that, ...

4 jours il y a | 0

Réponse apportée
Delay - bus as initial condition and bus propagation
I am intested in this question so I made an example. According to the document, 'The initial condition x0 port accepts nonvirtu...

5 jours il y a | 0

Réponse apportée
Simulation manager with initFcn
'InitFcn' is executed before the simulation starts, that is probably the reason that your parameter values set in the multiple s...

5 jours il y a | 0

Réponse apportée
What is the Matlab code that connects a variable to a Slider Switch Block?
The 'binding' needs to be a block in the model. If that block uses 'A' as a parameter and that parameter is selected to be bound...

10 jours il y a | 1

Réponse apportée
[Linux] Error in MatlabWindow after upgrading Ubuntu from 20.04 to 22.04
According to this, up to Ubuntu 18.04 LTS is supported by MATLAB R2018b. https://www.mathworks.com/content/dam/mathworks/mathwo...

11 jours il y a | 0

Réponse apportée
Force default datatype to single in undefined Simulink blocks
'DefaultUnderspecifiedDataType' is not the same as 'Default DataType'. Your setting only applies to the Constant block because i...

12 jours il y a | 0

| A accepté

Réponse apportée
How do I get the relative error between 2 signals in Simulink?
Assume x and y are the two signals, you are doing abs((x-y)/x) or abs((x-y)/y), when x or y is close to zero, it will cause di...

12 jours il y a | 1

| A accepté

Réponse apportée
Tally Instances of Negative Numbers in an Array (for loop)
A=load() returns A as a structure, not a typical matrix. If you make A an matrix, this code would work if you make the following...

14 jours il y a | 0

Réponse apportée
isnan to conver nan to zero in a table
T is an object of the class "table". You can't apply isnan() on it directly. Try the 'TreatAsMissing' option of the readtable() ...

14 jours il y a | 0

Réponse apportée
Is there a way to extract a list from "PV Array.ModuleName.Enum" to view the solar module data more efficiently?
Should be BlockDialogParameters.ModuleName.Enum or getfield(BlockDialogParameters.ModuleName,'Enum')

14 jours il y a | 0

Réponse apportée
Plot RGB triplets from a matrix as markers 'o'
Use 'color' to specify color in plot() x = linspace(0,10,10); y = linspace(0,10,10); xlabel('X-axis'); ylabel('Y-axis'); ax...

17 jours il y a | 0

Réponse apportée
What is the max number of digits allowed for a base 2 number?
The default data type in MATLAB is "double", which means 64 bits. When used to represent a base 2 number, its maximum value is 2...

20 jours il y a | 0

Réponse apportée
How to set Simulink block parameters using an absolute model path
The "absolute model path" of a block starts with the name of the model, not including the file folder where the model file is st...

25 jours il y a | 0

| A accepté

Réponse apportée
How to output text to Command Window if signal changes from 0 to 1 in Simulink
You might want to do that, but MATLAB and Simulink are quite different. I don't think you can do that because disp() or fprint...

environ un mois il y a | 0

Réponse apportée
I can't download Matlab R2022a release or earlier release
I can see many versions on this link. https://www.mathworks.com/downloads/

environ un mois il y a | 0

Réponse apportée
How to change const variable during simulink runtime
While the simulation is running, if you double click the Constant block, change its value from one numeric value to another (e.g...

environ un mois il y a | 0

Réponse apportée
Initial condition from external source for discrete integration diuring runtime
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e....

environ un mois il y a | 1

| A accepté

Réponse apportée
Function Call Trigger Problem
This "Outport" block seems to output a function call trigger. The message tells you what type of block can receive this signal. ...

environ un mois il y a | 0

Réponse apportée
A few basic Simulink/Simscape questions
run forever (tstop = inf) Yes. Set the simulation stop time to be inf store the trailing 10000 points Yes. Limit the data poi...

environ un mois il y a | 0

| A accepté

Réponse apportée
How the Delay one step block and stop time ( simulation time) infuence each other on simulink?
If you don't specify the step size or it is auto, the step size is automatically adjusted, influnced by simulation stop time and...

environ un mois il y a | 0

Réponse apportée
Simulink model output heavily dependent on relative tolerance
Not typical but is for a stiff system. Choose a stiff solver. https://www.mathworks.com/help/matlab/math/solve-stiff-odes.html

environ un mois il y a | 0

Réponse apportée
Issue in creation of test harness of a Simulink state in stateflow or creation of harness of a subsystem present in simulink state of stateflow.
I don't think a "system under test" can be a "state" in a state chart. A typical "system under test" has inputs, while a "state"...

environ 2 mois il y a | 0

Réponse apportée
Generate signal according to the the rising edges of two pulse generators in simulink.
A triggered subsystem shoud suffice. https://www.mathworks.com/help/simulink/slref/triggeredsubsystem.html

environ 2 mois il y a | 0

Réponse apportée
Matlab & Simulink crash at 2nd model run
After first run, execute "clear mex" or "clear functions" in MATLAB Command Window to see if it makes a difference.

2 mois il y a | 0

Réponse apportée
Avoid reuse of local variables in Embedded coder
That is probably not the correct option. You should try to disable the "Reuse local block outputs" option. https://www.mathwor...

3 mois il y a | 0

Réponse apportée
Switch multiport switch inputs based on time and order from user
There are many ways to do it. The easiest or most flexible way to do it is probably by using a MATLAB Function block. Use a Cloc...

3 mois il y a | 0

Réponse apportée
Attempting to turn off Dynamic Memory allocation but struggling to set variable size upper bound
Try allocating the variable in one shot, e.g. obj=struct('x',num2cell(rand(1,1000)))

3 mois il y a | 0

Réponse apportée
Can one Function call Trigger Multiple Subsystems?
Function-Call Split https://www.mathworks.com/help/simulink/slref/functioncallsplit.html

3 mois il y a | 0

| A accepté

Charger plus

Go to top of page