Design two digital filters with these specifications:
A lowpass IIR filter with passband and stopband frequencies of 0.65π rad/sample and 0.80π rad/sample, respectively. The passband ripple is 1 dB and the stopband attenuation is 50 dB.
A bandstop IIR filter with passband ripples of 1 dB and stopband attenuation of 50 dB. The passband frequencies are 0.25π rad/sample and 0.34π rad/sample. The stopband frequencies are 0.36π rad/sample and 0.45π rad/sample.
d1 = designfilt("lowpassiir", ... PassbandFrequency=0.65,StopbandFrequency=0.80, ... PassbandRipple=1,StopbandAttenuation=50); d2 = designfilt("bandstopiir", ... PassbandFrequency1=0.25,StopbandFrequency1=0.34, ... StopbandFrequency2=0.36,PassbandFrequency2=0.45, ... PassbandRipple1=1,StopbandAttenuation=50, ... PassbandRipple2=1);
Cascade the lowpass IIR and bandstop IIR filters to form a digital filter cascade. The filter uses normalized frequency.
d = cascade(d1,d2)
d =
digitalFilter cascade with properties:
Stages:
Stage1: [1×1 digitalFilter]
Stage2: [1×1 digitalFilter]
Specifications:
NormalizedFrequency: 1
Use filterAnalyzer to visualize filter
Use filter to filter data
Set the sample rate of the digital filter cascade to 2.5 kHz and display the filter properties. The filter uses the specified sample rate.
setSampleRate(d,2.5e3) d
d =
digitalFilter cascade with properties:
Stages:
Stage1: [1×1 digitalFilter]
Stage2: [1×1 digitalFilter]
Specifications:
NormalizedFrequency: 0
SampleRate: 2500
Use filterAnalyzer to visualize filter
Use filter to filter data
Display the SampleRate property for each stage of the digital filter cascade. Each stage uses the specified sample rate.
d.Stage1.SampleRate
ans = 2500
d.Stage2.SampleRate
ans = 2500
Input Arguments
Digital filter, specified as a digitalFilter object. Use designfilt to generate a digital filter based on frequency-response
specifications.
Example: d = designfilt("lowpassiir",FilterOrder=3,HalfPowerFrequency=0.5)
specifies a third-order Butterworth filter with normalized 3 dB frequency 0.5π
rad/sample.
Sample rate of the cascaded filter, specified as one of these:
"normalized"—setSampleRatesets the digital filterdto use normalized frequency.Positive scalar —
setSampleRatesets the sample rate of the digital filterdtoFsHz.
Data Types: char | string | single | double
Version History
Introduced in R2026a
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Sélectionner un site web
Choisissez un site web pour accéder au contenu traduit dans votre langue (lorsqu'il est disponible) et voir les événements et les offres locales. D’après votre position, nous vous recommandons de sélectionner la région suivante : .
Vous pouvez également sélectionner un site web dans la liste suivante :
Comment optimiser les performances du site
Pour optimiser les performances du site, sélectionnez la région Chine (en chinois ou en anglais). Les sites de MathWorks pour les autres pays ne sont pas optimisés pour les visites provenant de votre région.
Amériques
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)