Simulink missed some of the time values during simulation?
Afficher commentaires plus anciens
I simulate a performance of standard DC machine model (SimPowerSystems->Machines) and I use a pausing simulation block http://www.mathworks.de/help/toolbox/simulink/ug/f11-31373.html#f11-31548 but it doesn't work properly. For instance for pause value 2.55s the simulation doesn't pause at that time but continuing the simulation to the end.. If I set a pause value to 2.54 or 2.56 it works suitably. Why simulation doesn't pause at the time 2.55 (for any end time of the simulation)?
Réponse acceptée
Plus de réponses (2)
Nirmal Gunaseelan
le 19 Sep 2011
0 votes
The time steps chosen by Simulink depends on the type of solver (and the system that is being solved) that you have chosen. You can use the Data Inport/Outport tab in the Configuration parameters settings of the model to see what are the time steps that Simulink chose for the current simulation. If you are depending on the time step values (what is your use case?), you should be using Fixed-step solver where you can explicitly set the time step jumps.
Lukasz Wajdzik
le 20 Sep 2011