DAQ in Simulink can't find NI 6211 USB
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Data acquisition toolbox in Simulink can't find NI 6211 USB device. But DAQ tool in Matlab APPS find it without any problems. Using: Matlab 2015a 32bit, Windows 7 x64
0 commentaires
Réponses (3)
Shankar Subramanian
le 6 Juil 2015
Hi Ivan,
Data Acquisition Toolbox Simulink blocks support only the legacy interface and that too only on 32-bit MATLAB. Perform daqhwinfo and see if nidaq is listed on it. Try to execute daqhwinfo('nidaq') and see if your device gets listed. If it does not, you may not be having 32-bit drivers installed.
Thanks
Shankar
Fabrizio Gaspari
le 20 Avr 2016
Hello Ivan, I have the same problem! Did you solve it?
0 commentaires
Andrei
le 10 Août 2018
64-bit Simulink blocks from Data Acquisition Toolbox are available since MATLAB R2016b:
0 commentaires
Voir également
Catégories
En savoir plus sur National Instruments Frame Grabbers dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!