Simulink space vector PWM simulation

  • The model:
  • Here is what i intend to do.
  1. Generate three phase voltage
  2. Do a alpha beta transformation
  3. Do a Cartesian to Polar transformation
  4. Check the angle output
  5. Since the three phase vector rotates counter-clock wise, I am supposed to get sequence of angle moving from zero to 180 degrees and drops to -180(in no time!) and moves up and repeats itself.But result is that the angle sometimes reaches 172 degrees and turns around,not reaching 180 degrees.Waht is wrong? help!
  • Here is the result

 Réponse acceptée

MUHAMMED FASIL
MUHAMMED FASIL le 31 Août 2015

0 votes

Please resubmit ur valid mdl file or send me at tpfasil2007@gmail.com

1 commentaire

chen dunzhi
chen dunzhi le 1 Sep 2015
Modifié(e) : chen dunzhi le 1 Sep 2015
Thank you. The problem is solved.
The time step for simulation is not small enough, leading to insufficient accuracy.
And I changed the time step from 0.01 to 0.00002 and the result is just as expected.
Thank you again!

Connectez-vous pour commenter.

Plus de réponses (1)

MUHAMMED FASIL
MUHAMMED FASIL le 30 Août 2015

0 votes

Try with abc-AlphaBeta simulink block. Or submit ur mdl file

1 commentaire

chen dunzhi
chen dunzhi le 31 Août 2015
Modifié(e) : chen dunzhi le 31 Août 2015
The mdl file is there named reference_generation.mdl And i checked with abc-AlphaBeta block the result is the same. Does it have anything to do with the solver that Simulink uses? Because there is a warning:

Connectez-vous pour commenter.

Communautés

Plus de réponses dans  Power Electronics Control

Catégories

En savoir plus sur General Applications dans Centre d'aide et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by