Synchronizing 4 signals with 4 different measurefrequencies/timeintervals
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Dear Matlabusers,
I have 5 medical devices that measures 5 different kinds of biosignals (NIRS, EMG, ECG, FORCE, ANGULAR DISPLACEMENT)
EMG has a samplerate of 1250 Hz
ANGULAR DISPLACEMENT measures per 2 degrees displacement and records that time in 1/100 second. so max 100 Hz. (Force same device)
NIRS 8 Hz per second
Well, let's take the EMG-device as time-standard.
Now I want to synchronise them with the time so I want a dataset something like
Time EMG Angular displacement Force
0 0.15312 0 0
0.0004 0.15214 0 0
0.0008 0.13459 0 0
...
0.0100 0.26843 2 15
0.0104 0.21684 2 15
0.0108 0.21665 2 15
0.0112 0.21846 2 15
...
0.0200 0.35331 4 22
0.0204 0.35135 4 22
0.0208 0.35351 4 22
etc.
So i want the data of for example force to stay the same in the interval period it didn't measure (so I already have the data, not realtime) Force for example is:
0.00 0
0.01 15
0.02 22
0.03 25
0.04 28
I hope you understand what I mean :)!
I already coded the whole program for inserting the data, filtering etc. The syncing part is my only problem to complete this pilotstudy-program
Greetings and thanks in advance,
Martijn van Hooff
Réponse acceptée
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Multirate Signal Processing dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!