stateflow

3 vues (au cours des 30 derniers jours)
Murali Mohan
Murali Mohan le 15 Juin 2011
Hi all, Here I am using "after(0.025, sec)" in statechart for generating pulse, but when it wached on scope,its generating at 0.03, why is the difference. Can any help me how to make exact at 0.025.
  3 commentaires
Arnaud Miege
Arnaud Miege le 15 Juin 2011
Also, how often does your chart update?
Murali Mohan
Murali Mohan le 17 Juin 2011
sample time provided for the model is 0.01

Connectez-vous pour commenter.

Réponse acceptée

Gerd
Gerd le 17 Juin 2011
Hi Murali,
using a sample time of 0.01s for your model lets you only generate pulses with a multiple of the basic sample time(0.01 / 0.02 / 0.03) If you want to generate a pulse of 0.025 you have to increase your sample time to e.g. 0.001s
Gerd
  3 commentaires
Gerd
Gerd le 17 Juin 2011
Murali,
please open the model.
Double click on the upper chart "With absolute Time".
Change the transition to "After(0.025,sec)".
Hit Ctrl+E. Change the fundamental sample time to 0.001.
Open the scope and open Parameter pane. Go to "History".
Deselect Limit data points to last.
Run the model and observe the result.
I did these steps and the result is Ok
Murali Mohan
Murali Mohan le 17 Juin 2011
Thanks Gerd for your reply :)

Connectez-vous pour commenter.

Plus de réponses (0)

Catégories

En savoir plus sur Complex Logic dans Help Center et File Exchange

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by