Stop Simulink simulation base don a variable value
21 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance
0 commentaires
Réponse acceptée
Arnaud Miege
le 20 Juin 2011
Or use a Stop Simulation block. You will also need to construct the logic to create a boolean input signal to the block.
HTH,
Arnaud
0 commentaires
Plus de réponses (2)
Fangjun Jiang
le 20 Juin 2011
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.
0 commentaires
Voir également
Catégories
En savoir plus sur Simulink Functions dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!