A répondu
Could two rotational mechanical signals be added up/summed directly?
Hi Xu Based on your short description I would do as in the image below. This is often common for BEV models. The differential g...

environ 3 ans il y a | 0

A répondu
Flow meter measurement and control system
Hi Alex This type of task requires often modeling with foundation elements and in some cases create your own with Simscape l...

environ 3 ans il y a | 0

| A accepté

A répondu
Simscape- reverse operation for piston
Hello Aaron Indeed, this can be done with Simscape Fluids. All you need is two single-acting cylinders and represent the mech...

environ 3 ans il y a | 0

A répondu
Simulink Model of Regenerative Braking
Hi Daniel Check out the link below: https://se.mathworks.com/matlabcentral/fileexchange/62092-e-mobility-regenerative-braking-...

environ 3 ans il y a | 0

A répondu
Can anyone tell me how to model a regenerative braking system on simscape
Hello Abdel Check out the link below including a video on regenerative braking. https://se.mathworks.com/matlabcentral/fil...

environ 3 ans il y a | 0

A répondu
How to choose solver for a system that is stiff, partly continuous, partly discrete and has both Simulink and Simscape components?
Hello Mattias I think that a fixed step solver for Simscape (Local Solver) would help increasing performance. Try 1us or ...

environ 3 ans il y a | 1

A répondu
Distribuited load on flexible beams Simscape Multibody
Hi Alberto This can be done by adding the discrete nodes with help of rigid transforms. Unfortunately, the nodes will not ...

environ 3 ans il y a | 0

| A accepté

A répondu
Connecting DC motor to a revolute joint
Hi Vicente It shall work in both cases, but it is more natural to do it on the Simscape side (DC actuator). This makes sense ...

environ 3 ans il y a | 0

| A accepté

A répondu
Lead screw and spring WITH Simscape Driveline Toolbox
Hello Cyril The problem is that the speed sensor is coupled in series with the shaft, thus leaving the inertia isolated and t...

environ 3 ans il y a | 0

| A accepté

A répondu
Simscape Fluids Simple Pressure Drop Error
Hello Tiffy The gas starts up in a suction state, which means that vacuum would be created in the system. Such situations occ...

environ 3 ans il y a | 0

A répondu
SimScape Gas simulation error
Hello Federico Debugging such model is often difficult, and various settings may affect. My recommendation would be to reach ...

environ 3 ans il y a | 0

| A accepté

A répondu
Unable to supply a 1D array of current to the input of the controlled current source block
Hi Raiyan I believe that you should use From Workspace blocks. But these need the following format: [time_trace data_trace] s...

environ 3 ans il y a | 0

| A accepté

A répondu
Measuring SimScape friction torque
Hi Vivek I think that a torque sensor between the inertia and the friction element would work great. Br Juan

environ 3 ans il y a | 1

| A accepté

A répondu
simscape variable thermal mass - initial condition issue
Hello Benoit, It seems strange. Have you got the chance to share the files? BR/Juan

environ 3 ans il y a | 0

A répondu
How to get oscillatory motion for a solid in simscape?
Hello there, In order to do the work, I'd recommend to use Simscape Multibody to build the five-bar linkage mechanism. In Multi...

environ 3 ans il y a | 0

| A accepté

A répondu
Speed control and Position of DC motor using PID and Simscape
Hi Alejandro, Easiest is that you use a controlled DC voltage source. The output of the PID controller adjusting speed to the d...

environ 3 ans il y a | 0

| A accepté

A répondu
How to model a catch basin in simscape fluids
Hi there I think that the best way to solve that problem is to use a Local Resistance (Isothermal Liquid) between the end of th...

environ 3 ans il y a | 0

A répondu
Simscape-Multibody-Multiphysics-Library
Hi Andy Here is the link to the library. https://se.mathworks.com/matlabcentral/fileexchange/37636-simscape-multibody-multip...

environ 3 ans il y a | 0

A répondu
Ambiguous sorted order detected due to use of triggered subsystem(s) and/or Model blocks in a loop.
Hi there, I believe that you need to latch the incoming signals to the triggered subsystems. You do that in the Inport Simuli...

environ 3 ans il y a | 0

A répondu
modeling a solenoid coil
Hello Goutham I think you will find creating a Simscape component a better solution. Then, you can write the equations textua...

environ 3 ans il y a | 0

A répondu
Simscape interface with Simulink
Hi Don You can only connect physical inputs or outputs in Simscape to Simulink signals (through S-PS or PS-S Converters). C i...

environ 3 ans il y a | 0

| A accepté

A répondu
How to use matlab function output variable as a simscape block input variable?
Hi Youri, You need to create a custom thermal mass where cp is no longer a parameter but an input. Once you have created t...

environ 3 ans il y a | 0

A répondu
Simscape Multibody - Spatial Contact Force Block - Interference Fit modeling
Hello Hakan The interference fit is a complex phenomenon to model. I think that I would approach this as a prismatic joint wi...

environ 3 ans il y a | 1

A répondu
Lithium battery parameter estimation and SOC
Hi Glenn I’ll give a shot to the questions you have. 1. When this type of work is done with Simulink Design optimization,...

environ 3 ans il y a | 0

A répondu
Changing sequence of transformation of Simscape Multibody Joints
Hello Edwin It is likely that you need to compose your own joint to get the exact sequence you look for. To be sure, i would re...

environ 3 ans il y a | 0

| A accepté

A répondu
How to filter the current measurement before it enters a scope or signal analyzer
Hi Joseph If it is a physical signal (Simscape) for current, you’ll need a PS-Simulink converter to connect through to the filt...

environ 3 ans il y a | 0

A répondu
Can you create an S-Function from a Simscape Model?
Hi Tamam S-function generation from Simscape models is no longer supported from releases after 2015 or thereabouts. Deploymen...

environ 3 ans il y a | 0

A répondu
How to I simulate only heat exchanger outlet conditions?
Hello Tiffy What happens underneath is that the model has got too many state variables in relation to equations. In order ...

plus de 3 ans il y a | 0

| A accepté

A répondu
Parameter sweep using simscape
Hi Joshua Is the inductance parameter set as Run-time in the Simscape component? By default it is not, so maybe you can check...

plus de 3 ans il y a | 0

A répondu
Torque and Rotational motion sensor in simscape
Hi Leonardo Torque is a through variable measured with a torque sensor (TS) in series with the shaft of the motor. Speed is a...

plus de 3 ans il y a | 1