how to change initial conditions in Simulink?
7 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi,
I would like to change initial condition in Unit Delay Block in Simulink. Variable X is changing in algebraic loop and when its value stabilizes it should take this value as a new initial condition.
I set initial condition for X: X(1)=200 then when it achieves certain value, let's say 400 and from then it is constant, i want it as a new initial condition. I find it difficult because in algebraic loop this final value (400) is not a single number but it's an element of matrix (as the time changes).
How could it be done? Cheers
0 commentaires
Réponses (1)
Azzi Abdelmalek
le 20 Nov 2013
The initial value of a unit delay block is taken in account at the beginning of the simulation, what is the purpose of changing it?
1 commentaire
Voir également
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!