problem in designing state feedback controller

2 vues (au cours des 30 derniers jours)
Abdulaziz AlKuwari
Abdulaziz AlKuwari le 5 Jan 2014
I derived a model that is a Mimo model with 3 inputs and one output. I wanted to design a state feedback controller to control only one of the input because the others are constants that cannot be physically controlled. The approach I addressed is finding the transfer function of the desired control input to the output. Then I convert the system to state space so it turns to be siso system. Is my approach correct?
Thank you

Réponse acceptée

Azzi Abdelmalek
Azzi Abdelmalek le 5 Jan 2014
You can consider your model as SISO with two disturbance signals. Set those two constant signal to 0 and find the transfer function, and convert it to whatever you want (state space representation, or others)

Plus de réponses (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by