Error compiling Simscape network for model Loss_BuckConverter

1 vue (au cours des 30 derniers jours)
Shyam
Shyam le 5 Nov 2021
Modifié(e) : Shyam le 6 Nov 2021
I am getting the following error message while running 'Loss_BuckConverter' obtained from matlab file exchange, which was selected as the best pick that week. I would like to run the model. Could you please help in solving the error. Thank you.
Error compiling Simscape network for model Loss_BuckConverter.
Caused by:
['Loss_BuckConverter/Simscape Thermal Model/Thermal Mass (Case)']: Type mismatch for equation. The left hand side of the equation is {[1x1 double], 'C'} and the right hand side of the equation is {[1x1 double], 'K'}. In foundation.thermal.elements.mass (line 33)
T = {[1x1 double], 'C'}
M.T = {[1x1 double], 'K'}