Error with Vsim command
Afficher commentaires plus anciens
Hi all,
I need to use Simulink with altera modelsim v6.6c. But when I use command vsim('socketsimulink', 4449), I get errors below
??? SWITCH expression must be a scalar or string constant.
Error in ==> hdlsim>l_GetModelSimLibInfo at 549
switch (lfmVer)
Error in ==> hdlsim at 113
case 'ModelSim', libInfo = l_GetModelSimLibInfo;
Error in ==> vsim at 101
hdlsim(pvpairs{:});
How can I fix this error? I use Matlab R2010a
Thanks a lot!
Best Regards!
2 commentaires
Kaustubha Govind
le 30 Sep 2011
What is the output of this command when you run it in MATLAB:
[s, fullver] = system('vsim -version')
Nguyen The Man
le 1 Oct 2011
Réponses (2)
Nguyen The Man
le 30 Sep 2011
0 votes
1 commentaire
Fangjun Jiang
le 30 Sep 2011
I think Walter's answer is probably the solution. Check the document.
http://www.mathworks.com/help/toolbox/edalink/ref/vsim.html
Walter Roberson
le 30 Sep 2011
vsim('socketsimulink', '4449')
That is, the socket information must be supplied as a string.
1 commentaire
Nguyen The Man
le 1 Oct 2011