Simulink Design Verifier Problem
Afficher commentaires plus anciens
if trackID>0
mioState = confirmedTracks.Tracks(trackID).State;
else
mioState = inf(numStates,1,'like',confirmedTracks.Tracks(1).State);
end
while i'm doing the simulink design verifier for ACC model i'm getting this error in "find lead car" function
in this i have used inf(infinite array)
Non-finite number is used. Simulink Design Verifier does not support non-finite numbers. Function 'Tracking and Sensor Fusion/Find Lead Car' (#1689.1857.1912), line 48, column 16
can someone solve this error?
Réponses (1)
Yatharth
le 1 Sep 2023
Hi Mohammad, I understand that you are encountering the error , "Non-finite number is used" in Simulink Design Verifier.
To resolve this error, you can modify your code to use a large finite number instead of "inf". Here's an example of how you can modify the code snippet you provided:
if trackID > 0
mioState = confirmedTracks.Tracks(trackID).State;
else
mioState = ones(numStates, 1) * 1e10; % Use a large finite number instead of inf
end
I hope this helps.