Pass input timeseries and block values into the sim command
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Yevgeniy Gorbachev
le 5 Fév 2023
Commenté : Yevgeniy Gorbachev
le 6 Fév 2023
Hi,
Is there a way to pass Simulink models inputs into the sim call as opposed to "From Workspace" blocks (for signals) or workspace-named variables (for mask parameters)?
e.g, instead of
V_in = timeseries(0:0.05:10 > 2, 0:0.05:10);
K = 10;
sim("my_simulation");
I would use something like
input_voltage = timeseries(0:0.05:10 > 2, 0:0.05:10);
motor_gain = 10;
sim("my_simulation", "V_in", input_voltage, "K", motor_gain); % (if I have blocks that expect things named V_in and K)
Thank you!
0 commentaires
Réponse acceptée
Paul
le 5 Fév 2023
Hi Yevgeniy
Use a Simulink.SimulationInput object. More generally start from Run Simulations and follow the doc pages from there for more details.