switch case
24 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
shahid Alam
le 28 Oct 2011
Commenté : ahmed al-kady
le 9 Nov 2015
i need help here...to run a system in simulink an error is showed : Port 2 of 'final/Subsystem4/Subsystem2/Switch Case' can only be connected to an action subsystem and may not be connected to more than one action subsystem....if possible plz help me here.....
0 commentaires
Réponse acceptée
Fangjun Jiang
le 28 Oct 2011
The message is clear. The output of the "Switch Case" block can only be connected to one (and only one) "Switch Case Action Subsystem" block, which can be found in library "Ports & Subsystems". Remember to connect the "Action Port", not the "Inport".
Open sl_subsys_sw1.mdl to see an example.
0 commentaires
Plus de réponses (1)
shahid Alam
le 28 Oct 2011
2 commentaires
Fangjun Jiang
le 28 Oct 2011
The output of the "Switch Case" block is a trigger. It can only trigger one subsystem. If you need to trig more than one, you can probably put all the things that you want to trig inside the "Switch Case Action Subsytem".
You can add as many Inport blocks as you want.
ahmed al-kady
le 9 Nov 2015
please i need to reset the switch case after triggering another case, as it hold the output even if the input signal is changed. thanks in advance.
Voir également
Catégories
En savoir plus sur Schedule Model Components dans Help Center et File Exchange