Effacer les filtres
Effacer les filtres

What are the units of data (specifically dose) to be input in sbionca

2 vues (au cours des 30 derniers jours)
Aijaz Shaliban
Aijaz Shaliban le 31 Mai 2023
Commenté : Aijaz Shaliban le 1 Juin 2023
The dose dependent outputs of sbionca - 'C_max_Dose' and 'AUC_infinity_dose' should be equal to C_max/Dose and AUC_infinity/Dose.
eg: If C_max = 10300000 ng/ml and Dose = 400000000 ng/kg
then C_max_Dose = C_max/Dose should be 0.0257 (ng/ml)/(ng/kg)
But, the output of sbionca for C_max_Dose is 25.75 (1000 times higher).
Please let me know if there is any mistake I am making while inputting the data or anything else.

Réponses (1)

Rick Paxson
Rick Paxson le 31 Mai 2023
Hello,
This is not your mistake but rather ours. There is a bug with unit conversion in NCA.
C_max_Dose is (silently) being reported in g/mL rather than kg/ml. This affects AUC_infinity_dose as well.
We will fix this asap.

Communautés

Plus de réponses dans  SimBiology Community

Catégories

En savoir plus sur Import Data dans Help Center et File Exchange

Produits


Version

R2019b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by