Problem by importing data into simulink as "Array From Workspace"
20 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Anna B.
le 12 Juil 2023
Réponse apportée : Nils Hornik
le 13 Juil 2023
invalid workspace variable specified as workspace input in 'power_controlcurr/Array From Workspace'. Time values must be non-decreasing.
3 commentaires
Harald
le 13 Juil 2023
Hi Anna,
it is difficult to tell why Simulink would error because of a variable having to be non-decreasing when you say it is.
If possible, please upload the model and the required data. Both can be trimmed down to what is needed to reproduce the problem.
Best wishes,
Harald
Réponse acceptée
Nils Hornik
le 13 Juil 2023
Hi Anna,
For this Block the "time values must increase monotonically" as stated here in the doc: Load Data Using the From Workspace Block - MATLAB & Simulink (mathworks.com)
In such cases I would reccomend to use the following functions to find out where in a (potentially large) time vector a decrease occurs.
- issorted() to find out if there are non-increasing elements in the vector
- find() e.g.: find(diff(t)<0) to find the effected indecies/lines
Hope that helps,
Nils
0 commentaires