unable to resolve cooling plate error

2 vues (au cours des 30 derniers jours)
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT le 26 Juil 2023
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  3 commentaires
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT le 26 Juil 2023
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo le 27 Juil 2023
I have the same problem, did you solve it?

Connectez-vous pour commenter.

Réponse acceptée

Joel Van Sickel
Joel Van Sickel le 28 Juil 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.