unable to resolve cooling plate error
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
SUDEEP SINGH RAWAT
le 26 Juil 2023
Réponse apportée : Joel Van Sickel
le 28 Juil 2023
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
3 commentaires
Réponse acceptée
Joel Van Sickel
le 28 Juil 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.
0 commentaires
Plus de réponses (0)