Using block variant source in mask
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello, I am not able to make it read the value of the variable "test" chosen in the mask. If anyone can help me please.
0 commentaires
Réponses (1)
Dinesh
le 3 Juil 2024
Hi Rafaela.
I think that you have defined the variant control expression using "Simulink.VariantExpression" which is currently not supported for mask workspace variables. Please refer to the following highlighted documentation link: https://www.mathworks.com/help/simulink/ug/approaches-to-control-active-variant-choice-of-a-variant-block.html#:~:text=Do%20not%20support%20using%20Simulink.VariantExpression%20objects%20or%20Simulink.Parameter%20as%20variant%20control%20variables.
Instead of using "Simulink.VariantExpression" objects, you could define the variable "test" directly in MATLAB workspace and modify the "Variant Source" dialog to have "test==1" and "test==2" under "Variant control expression" for Port 1 and 2 respectively. Along with this, you can modify the workspace parameter to have values "1" and "2" in the dropdown. I tested this approach and it works perfectly fine and the variant choice is chosen during compile depending on the value specified in the mask.
I hope this helps.
0 commentaires
Voir également
Catégories
En savoir plus sur Outputs dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!