How to take out temperature data of one battery cell from battery pack to use it for controller design?
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
SUDEEP SINGH RAWAT
le 14 Déc 2023
Commenté : SUDEEP SINGH RAWAT
le 16 Déc 2023
Hi,
i am in process of designing a battery pack with liquid cooling. I have used pump to flow the coolant inside the battery pack. The pump shall operate above the upper temperature limit value and shut off when the temperature of the battery cell is within limits. But for that, i need temperature of the single cell from the group of cells. Any suggestion in this regard will be highly helpful for me.
PS: This "goto" block name TEMP_CELL is taking all data of 25 cells but i need only 1 cell data and then i fed it to the controller.
0 commentaires
Réponse acceptée
Fangjun Jiang
le 14 Déc 2023
Use the Selector block. The dialog might be intimidating to some. For your case, change the "Inport port size" from "3" to "25", and change the "Index" column from "[1 3]" to "1" for picking the first cell or "25" for picking the last cell.
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Battery Pack Modeling dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!