Effacer les filtres
Effacer les filtres

AUTOSAR Classic System Composer Client Server Interfaces

7 vues (au cours des 30 derniers jours)
Melih
Melih le 11 Mar 2024
Commenté : Feimi le 16 Avr 2024
I am trying to create an arcitecture on System Composer, want to design client server interfaces. Is there a limitation for AUTOSAR Classic plathform, because I am receiving errors while doing this. The error says
Unable to export model 'TestModel' to AUTOSAR architecture. Consider removing the following element(s) from the architecture:
Caused by:
  • Client and server ports are not supported in Classic AUTOSAR architectures.

Réponses (1)

Feimi
Feimi le 15 Mar 2024
Hi Melih,
This is a limitation that Classic AUTOSAR architecture does not support client/server ports as of MATLAB 2023b. For a complete list of the limitations in exporting from software architecture to AUTOSAR architectures, please find the documentation here:
Feimi
  2 commentaires
Melih
Melih le 12 Avr 2024
ok good to know, handle many interfaces is a problem in system composer. SR interfaces work well, but other ones, do you suggest using shared Autosar params in a sldd?
Feimi
Feimi le 16 Avr 2024
Hi Melih,
In MATLAB R2023b and later versions, you can use architecture data editor with AUTOSAR Classic platform mapping to edit NV and MS interfaces:
https://www.mathworks.com/help/autosar/ref/architecturaldataeditor.html
For CS interfaces, since they cannot be modeled in AUTOSAR Classic Architecture models, they need to be configured in the Simulink model. Please refer to this article on how to configure C-S communication in a Simulink model:
Feimi

Connectez-vous pour commenter.

Produits


Version

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by