- Open up the scope
- Click the gear button (Preferences/Options)
- Go to the "History" tab and uncheck the "Limit data points to last" box
- Run the simulation again to collect the data''
Data is not visible by simulink plot block
4 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi...
When I attempt to see my plot in Simulink, it only shows me a specific x-range different than what I had chosen in advance. For instance, I chose "simulation stop time" =1000 but when I see the result from the scope block I can see only the range (980-1000). Why this happens? and how can I fix it?
Thanks in advance
0 commentaires
Réponses (1)
Sebastian Castro
le 30 Avr 2015
Modifié(e) : Sebastian Castro
le 30 Avr 2015
By default, Scope blocks retain only the last 5000 data points to save on memory. If you want all the data to show up:
EDIT: If it's not that, there is also a "Time range" option in the first tab of the Scope block preferences. Sometimes this gets changed to values smaller than your total simulation time, so look out for that too.
- Sebastian
0 commentaires
Voir également
Catégories
En savoir plus sur View and Analyze Simulation Results dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!