How to create a switch command between adsorption and desorption in Simulink?
2 commentaires
Rahul
le 4 Oct 2024
Hey @Ababacar Thiam, can you share your Simulink Model, or describe your use case, that'll help in better understanding the isssue.
Réponse acceptée
Altaïr
le 8 Oct 2024
To switch between the two subsystems (adsorption and desorption) based on a control signal, the ‘Switch’ block can be used. The control signal can be generated in a couple of ways:
- Using ‘Relational Operator’ and ‘Logical Operator’ blocks if the switching logic is simple.
- For more complex switching logics, a ‘Stateflow’ chart can be used.
You can learn more about the ‘Switch’ block in the following documentation page.
Here’s an example for the ‘Switch’ block that outputs the absolute value of a biased sine wave. The below model switches between ‘subsystem1’ and ‘subsystem2’ depending on the value of ‘controlSignal’.
The output seen in the scope would be as follows:
You can refer to the attached model for further assistance. To switch between several subsystems, the ‘Multiport Switch’ block can be used. Feel free to check out the following documentation page.
I believe this will assist you!