FMU issue while setting parameter

17 vues (au cours des 30 derniers jours)
Saurabh Dhakate
Saurabh Dhakate le 28 Oct 2024 à 16:06
Réponse apportée : Gayatri le 28 Oct 2024 à 16:11
We have an FMU that imports successfully into Simulink. However, I'm struggling to set parameters from the workspace. I've tried using various Simulink callbacks but it doesn't seem to affect the FMU's parameters. I want to set parameters once at the start of the simulation.

Réponse acceptée

Gayatri
Gayatri le 28 Oct 2024 à 16:11
Hi Saurabh,
You can modify the parameters using the following MATLAB commands:
blockPath = 'model_name/block_name';
blockHandle = getSimulinkBlockHandle(blockPath, true);
set_param(blockHandle, 'parameter_name', 'parameter_value');
Please refer the below documentations for 'set_param' and 'getSimulinkBlockHandle' functions:
I hope it helps!

Plus de réponses (0)

Catégories

En savoir plus sur RF Blockset Models for Transceivers dans Help Center et File Exchange

Produits


Version

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by