FMU issue while setting parameter

6 vues (au cours des 30 derniers jours)
Saurabh Dhakate
Saurabh Dhakate le 28 Oct 2024
We have an FMU that imports successfully into Simulink. However, I'm struggling to set parameters from the workspace. I've tried using various Simulink callbacks but it doesn't seem to affect the FMU's parameters. I want to set parameters once at the start of the simulation.

Réponse acceptée

Gayatri
Gayatri le 28 Oct 2024
Hi Saurabh,
You can modify the parameters using the following MATLAB commands:
blockPath = 'model_name/block_name';
blockHandle = getSimulinkBlockHandle(blockPath, true);
set_param(blockHandle, 'parameter_name', 'parameter_value');
Please refer the below documentations for 'set_param' and 'getSimulinkBlockHandle' functions:
I hope it helps!

Plus de réponses (0)