adaptive model predictive control
3 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
In the following link (or above picture) in the controlled system, why are the initial inputs and outputs are subtracted from system inputs/outputs and the resulting signals then delayed? I have indicated these parts in a red rectangle.
0 commentaires
Réponse acceptée
Arkadiy Turevskiy
le 18 Mai 2015
The intitial values are substracted to remove the offset from the data. The delay block resamples continuous signals coming from the plant model, as the estimator requires discrete-time signals sampled at Ts. You could use Rate Transition block instead.
Hope this helps.