Initial condition from external source for discrete integration diuring runtime

6 vues (au cours des 30 derniers jours)
I have a discrite integration with simulink and externaly added the condition:
when changing the value of external source (in my case mec_init_pos) - does it have influence on simulation integration or just for strating simulation and very first initialization of the integration?

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 17 Jan 2025
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e.g. t=0) would be taken to set the initial value of the integrator.
When you enable "external reset", then the dynamic value could be taken depending on the external reset signal.