DAQ at multiple sampling rates with one NI device using analog input

3 vues (au cours des 30 derniers jours)
Csaba
Csaba le 25 Nov 2011
Hello everyone!
I'm wondering if there is any possibility of DAQ at different sampling rates using one NI device. I tried to find some documentation but with not much success. Any references?
I thought at some solution starting more than one analog input objects or setting different sampling rates for the channels. Anyone already tested some of these solutions or have another one to propose ?
Thanks in advance, Best regards,
Csaba

Réponse acceptée

Daniel Shub
Daniel Shub le 26 Nov 2011
The only current device that allows multiple analog input sampling rates is the Compact DAQ NI 9174 and NI 9178.
Assuming you have one of these devices, then it should be possible. It probably is not currently possible in MATLAB since I would guess that it falls into the
If specialized analog measurement capabilities such as hardware clocked digital I/O are valuable to you, please let us know by completing the form at the bottom of this page.

Plus de réponses (1)

Csaba
Csaba le 27 Nov 2011
Thanks for the references.
Csaba