How to get unity power factor in three phase rectifier by hysteresis current controller
Afficher commentaires plus anciens
attain unity power factor in input side by hysteresis current controller
Réponses (5)
Anees Ansari
le 20 Juin 2015
0 votes
Purushottama Rao
le 20 Juin 2015
0 votes
Steps: 1) Sample the input line voltage signal. Use a PLL for syncronization, the output of which is a unit mag sinusoidal signal inphase with the line voltage. 2) Prepare the ref current. This can be obtained by multiplying the required curret rms value with the PLL output. 3) Measure the input current 4) Calculate the error between the above two currents 5) Define a hystresis controller with the defined hystersis level. Relay block in simulink does this for you. Hystersis limits defines the switching frequency and THD. 6) Pass the output from hystersis to the switches directly.
It should give you the required output. ALL THE VERY BEST
4 commentaires
Anees Ansari
le 20 Juin 2015
Purushottama Rao
le 22 Juin 2015
I propose to have your model or a print screen of it to fix it.
Anees Ansari
le 24 Juin 2015
Anees Ansari
le 24 Juin 2015
Anees Ansari
le 24 Juin 2015
0 votes
Anees Ansari
le 24 Juin 2015
0 votes
3 commentaires
Purushottama Rao
le 25 Juin 2015
Modifié(e) : Purushottama Rao
le 25 Juin 2015
Dear Anees, Thanks for the info. Picture was not clear especially the lower power part Below the diode bridge.I would like to see what is there inside it?
I could not find any return path other than the diode bridge for the phase current. Gv more details. Share your model for better help