How to tune PID for a Output(t) = k*Input(t) system?

1 vue (au cours des 30 derniers jours)
Richie
Richie le 10 Août 2015
Clôturé : MATLAB Answer Bot le 20 Août 2021
Hi,
Here comes a very simple system: Output(t) = k * Input(t), And a control reference of 1 is to be achieved.
I am adding a feedback PID controller to the system. I have two questions:
1. Is it correct to say that adding a PID controller with P is enough?
2. Is P = 1/k? Since if we make P = 1/k, in theory, the adjustment will be (-1/k*error), then the system will be perfectly compensated.

Réponses (1)

Arkadiy Turevskiy
Arkadiy Turevskiy le 13 Août 2015
Plant model does not have an integrator in it, so you need an integral term to achieve zero steady-state error. In other words, if the controller is simply Kp, closed loop transfer function in Kp*K/(1+Kp*K). For Kp=1/K, closed loop transfer function is 1/K*K/(1+1/K*K)=1/2=0.5.
To get zero steady state error you need to add an intergral control. Integral control is all you really need in this case. Hope this helps.