All switches and circuit breakers in Simpower specialized tech blocks have leakage due to their snubbers and/or parallel resistors, etc. which actually keep the disconnected circuits in simulation profile. How can I disconnect them like a real world contactor/relay out of a circuit?
Réponses (2)
Sebastian Castro
le 31 Mar 2016
Modifié(e) : Sebastian Castro
le 31 Mar 2016
0 votes
You should be able to set the snubber values of inf, which makes them ideal. Even the block icons should change to remove the snubbers!
Alternatively, if your model is running in Continuous mode (as per the powergui block), there is an "Enable use of ideal switches" option available in that block.
Under the hood, Simscape Power Systems won't get rid of the components when you open a breaker, but it will decouple the state-space matrices on either side of the switch so you're effectively solving two separate systems.