No Flow in a basic hydraulic system

7 vues (au cours des 30 derniers jours)
alarson52
alarson52 le 16 Mai 2016
Commenté : alarson52 le 13 Juin 2016
See attached picture. I have modeled a very simple hydraulic system and pressure readings are as expected, but I am reading no flow. I've double-checked all of my parameters and nothing seems out of line. What am I missing here?
  2 commentaires
Mika Herranen
Mika Herranen le 10 Juin 2016
You need a 'Hydraulic flow rate source' instead of tank.
alarson52
alarson52 le 13 Juin 2016
Actually, the tank is fine. Sebastian's answer is correct. The system works fine if the pressure gauge is connected in parallel.

Connectez-vous pour commenter.

Réponse acceptée

Sebastian Castro
Sebastian Castro le 11 Juin 2016
I think the problem is your Hydraulic Pressure Sensor is connected in series, and is acting as an infinite resistance. Flow sensors go in series; pressure sensors go in parallel.
Make sure you connect that sensor in parallel, so there is a flow path from the tank all the way through the reference.
- Sebastian
  1 commentaire
alarson52
alarson52 le 13 Juin 2016
Thanks, this is correct!

Connectez-vous pour commenter.

Plus de réponses (0)