Using set_param with Configuration Set Reference

14 vues (au cours des 30 derniers jours)
Dave Walter
Dave Walter le 7 Juil 2016
Commenté : Krishna Akella le 28 Oct 2022
I have a medium sized Simulink project using Configuration Reference to tie all the submodels (Model Reference) to one Configuration set. Is there a way to change the configuration parameters from the command line using set_param? I get the error:
A configuration set reference does not allow writing to parameters in the source configuration set

Réponses (1)

Tiago Grossinho
Tiago Grossinho le 18 Juil 2017
Hello,
You probably have your question answered 1 year later, but for reference, I found my answer in the following page:
Chapter " §Change Values in a Referenced Configuration Set". Indeed, if you " Get" the config set which corresponds to the active one in your model, the set_param operation will immediately set the value in the model. My example:
>> get_param('model_name','RTWCAPISignals')
ans =
on
>> cref=getConfigSet('model_name','Reference');
>> cset = cref.getRefConfigSet;
>> set_param(cset,'RTWCAPISignals','off');
>> get_param('model_name','RTWCAPISignals')
ans =
off
Hoping it may help someone in the future, or even myself when I forget it one day! :)
  2 commentaires
Gergely Takacs
Gergely Takacs le 9 Mai 2022
Thank you for the tip. Not entirely user friendly to figure this out:)
Krishna Akella
Krishna Akella le 28 Oct 2022
Thanks, it helped me today!