Different plots using rocpfa
10 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I got different plots using rocpfa for 1 pulse with Coherent and Non-Coherent integrations. However, it should give the same answer.
0 commentaires
Réponses (1)
Honglei Chen
le 8 Août 2016
I think you probably refer to the case where you take the magnitude of the signal to do the detection and in that case I agree with you. However, in rocpfa, the coherent case means that you don't have to use the magnitude. Instead, you can do a perfect match and only deal with noise in the I channel. Hence the threshold will be different and therefore the Pd are a bit different too.
0 commentaires
Voir également
Catégories
En savoir plus sur Detection dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!