Why parameter " yout " doesnt exist to workspace ?
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
HamidReza Saleh
le 15 Sep 2016
Commenté : HamidReza Saleh
le 16 Sep 2016
Hi I try to sent one parameter from simulink to workspace the parameter i seek is variable from block yout in powergui i checked the mark from model configuration yout but doesnt show in workspace do you have any suggestion ??
0 commentaires
Réponse acceptée
Walter Roberson
le 15 Sep 2016
How are you starting the model running? If you are starting it from MATLAB using sim() then the variable would normally end up in the workspace of the function you ran sim() from.
10 commentaires
Walter Roberson
le 16 Sep 2016
I had another look. There does not appear to be a yout there. There is a Yout (capital Y) which is a subsystem (not a signal), with the subsystem having a Demux block that sends the individual elements to a whole bunch of different blocks.
If you are trying to get a copy of that signal before demuxing, you will need to add a tap off of the source of that subsystem, v,i and have a Save To Workspace block there. I do not find a To Workspace block there.
Plus de réponses (0)