Effacer les filtres
Effacer les filtres

Needle Valve control: What is the physical port S meaning?

1 vue (au cours des 30 derniers jours)
Paolo
Paolo le 11 Nov 2016
Commenté : Paolo le 12 Nov 2016
I have a Needle Valve with the following parameters:
Orifice diameter: 1 inch
Needle cone angle: 179 deg
Initial opening: 0 m
Flow discharge: 0.1425
Other parameters as default.
Connected to the Physical port S i have a Physical constant, i set up to control the flow through the valve.
I don't understand, and i couldn't find any evidence on the official help, how does this Physical signal works: apparently the valve is full open (no flow cut) for S:0.00635. Where does this number come from?
I found this value simply reducing S until the flow rate started to decrease. How is S connected to the opening?
Thank you very much in advance.

Réponse acceptée

Andrew Schenk
Andrew Schenk le 11 Nov 2016
The port S represents the variable x in the equations listed on:
Since the PS constant block does not have a unit, the value should be entered in meters. Finally, double check the cone angle you have specified since 179 deg is very near flat.
  1 commentaire
Paolo
Paolo le 12 Nov 2016
Thank you. Actually I put 179 deg because from the sketch provided in its datasheet (attached) the cone angle seems to be very flat. Is it a mistake? Should I use another valve block?

Connectez-vous pour commenter.

Plus de réponses (0)

Catégories

En savoir plus sur Simscape Fluids dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by