SINEWAVE IN SCOPE (simscape)
3 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello, I connected an ac voltage source to a voltage sensor and then trough a ps-to-simulink converter to a scope, in order to see the voltage graph. I use an ode23t solver and the only thing I get is a straight line on the x axis (with value ewual to 0). No sinewave looking voltage/ I set simulation time to 0.1. Why is this happening? Do I need to use different blocks? SCOPE is not appropriate for simscape and physical signals?
Thanks
0 commentaires
Réponse acceptée
Doug Eastman
le 3 Avr 2012
To see the sinusoidal voltage variation you need to reduce the step size of the simulation. Go to Simulation -> Configuration Parameters and change the Max step size parameter to be smaller than 1/(2*frequency). For example if the AC frequency is 60 Hz, set the parameter to be 1/120 or 1/240.
1 commentaire
K E
le 3 Avr 2012
This blog entry may be helpful, http://blogs.mathworks.com/seth/2009/07/14/refining-the-output-of-a-simulation/
Plus de réponses (1)
Voir également