Simscape Full-Bridge Error
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I'm using a PWM generator as the gate signal for the full-bridge block. I want to simulate a single phase full-bridge inverter. I'm getting an error that says since the pwm generator has an 8 pulse output and the converter block is only 4 pulses, it won't work.
Can someone tell me what I'm doing wrong and how to simulate a single-phase full-bridge inverter with this block? (The example is no help)
I've attached a few illustrative pics. Thanks!
<<
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/165647/image.png)
>>
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/165648/image.png)
0 commentaires
Réponses (1)
Joel Van Sickel
le 2 Sep 2020
Hello Ryan,
you are using a PWM generator designed for a 3 level inverter. This is a 2 level full-bridge. Please use the 2 level PWM generator, and select the appropriate topology (it will default to a 6 device inverter, but can be set to work for a full-bridge).
Regards,
Joel
0 commentaires
Voir également
Catégories
En savoir plus sur Switches and Breakers dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!