Is the n4sid model an LTI model?

2 vues (au cours des 30 derniers jours)
LEI CAO
LEI CAO le 12 Avr 2012
I have a prediction model derived by n4sid.
when I set the variables with setmpcsignals for MPC controller, it is warned "The first input argument of the "setmpcsignals" command must be a non-empty "lti" object".
Isn't an idss model LTI?
  3 commentaires
LEI CAO
LEI CAO le 12 Avr 2012
I guess the problem is in the matrix K.
The idss model is
x(t+Ts)=Ax(t)+Bu(t)+Ke(t)
y(t)=Cx(t)+Du(t)+e(t)
The matrix D=0, K is not zero.
When I set K=0, the alarm doen't occur any more. But the model is not good enough then.
Is there any mothod to overcome this issue?
Rajiv Singh
Rajiv Singh le 12 Oct 2012
What matlab release are you using? Could you post some reproduction steps? As such, an estimated idss model should be usable in MPC and you should not have to set K to zero.