Simulink filter simulation

1 vue (au cours des 30 derniers jours)
sana
sana le 27 Mar 2011
Hello everyone,
I have a digital filter and i need to send a large data set through that filter, problem is I have to set "simin" variable which is the input data that i am sending through the filter, therefore i have to read all the data to memory, Is there an alternative way of simulating the design. My data size is around 200Mb.
thank you, sana.

Réponses (1)

Seth Popinchalk
Seth Popinchalk le 29 Mar 2011
Save your data to a file and use the From File block. This will enable incremental reading of the data from the file during the simulation and minimize the amount of memory used.

Catégories

En savoir plus sur Single-Rate Filters dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!