Phase to phase voltage in Three-Phase Source
24 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I'm using Simscape features in Simulink. In the "Three-Phase Source" block the setting of the "Phase to phase voltage" parameter is defined as RMS. But I can not get the nominal values. I can only apply a division by root of 2. Is it right or am I making a mistake?
0 commentaires
Réponses (1)
Joel Van Sickel
le 2 Sep 2020
Hello Ademir,
the RMS voltage is Vpeak/sqrt(2). Vline to line = Vphase*sqrt(3). It sounds like you are doing it correctly.
Regards,
Joel
2 commentaires
Maya
le 5 Oct 2023
I am using the Simscape 3 pahse source ( specialized Power systems) to power a 3 phase induction motor. However, I observe that the phase to phase voltages between the three phases are showing slightly different values. None of the values match the setting of the model namely 400V rms. The .slx file is attached. ![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1502394/image.jpeg)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1502394/image.jpeg)
Joel Van Sickel
le 9 Oct 2023
Hello Maya,
you have your source set to 50 hz but the RMS blocks set to 60 hz. They need to the be same for the calculation to work.
Regards,
Joel
Voir également
Catégories
En savoir plus sur Electrical Sensors dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!