How can I control signal logging in referenced models?

15 vues (au cours des 30 derniers jours)
Paul
Paul le 26 Jan 2011
AFAIK, the only way to control signal logging in a referenced model is by right clicking on the model block and pulling up the Model Reference Signal Logging dialog. Is there a way to control signal logging in the referenced model programatically? Can it be done through model arguments so as not cause a rebuild?

Réponses (2)

Vieniava
Vieniava le 26 Jan 2011
Try this:
Z=get_param('YourModel/BlockName','PortHandles');
set_param(Z.Outport, 'DataLogging', 'on');
Where: YourModel is your simulink model name and BlockName is name of block which output signal you'd like to log.
  1 commentaire
Paul
Paul le 27 Jan 2011
I don't think this can work when the block in question is a Model Reference and I'm trying to control the logging of signals inside the referenced model.

Connectez-vous pour commenter.


Vieniava
Vieniava le 27 Jan 2011
Phisically go to the block inside referenced model. Next find a handle to this block via
H=get_param(gcb,'Handle);
then
Z=get(H,'Porthandles');
set_param(Z.Outport, 'DataLogging', 'on')
it should work now.
  1 commentaire
Paul
Paul le 27 Jan 2011
This would work for one reference, but doesn't provide independent control over multiple references to the same model, such as can be achieved using the Model Reference Signal Logging dialog.

Connectez-vous pour commenter.

Catégories

En savoir plus sur Prepare Model Inputs and Outputs dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by