Effacer les filtres
Effacer les filtres

Model_X has multiple sample times error

54 vues (au cours des 30 derniers jours)
ricard molins
ricard molins le 20 Fév 2019
Réponse apportée : dc le 23 Avr 2023
I am getting the following error
'MyTopLevelModel/SubsystemA/Model' has multiple sample times. Only constant (inf) or inherited (-1) sample times are allowed in function call subsystem 'MyTopLevelModel/SubsystemA'.
More info of my setup
SubsystemA has a function call which has a trigger port connected to a port set as "output function call with sample time of 0.001. All my other blocks have sample time -1 (inheritet).
If I go to the model explorer the compiled sample time are not [-1 0] some of the have set the [0.001 0]
Any idea what could be causing this error ?
  3 commentaires
ricard molins
ricard molins le 20 Fév 2019
Can't share the model. Thats the reason I am asking for guidance of where could the potential error be and not a specific solution to my issue.
Arvind Sathyanarayanan
Arvind Sathyanarayanan le 20 Fév 2019
To identify which block(s) have a different sample time goto Display ->Sample TImes -> Colors.

Connectez-vous pour commenter.

Réponse acceptée

ricard molins
ricard molins le 22 Fév 2019
The problem was that a configuration reference had a time step set to 0.01. This time step was transformed into a CompiledTimeStep and therefore it set a CompiledTimeStep different to -1 or inf. Setting the time step to auto solved the issue.

Plus de réponses (1)

dc
dc le 23 Avr 2023
it is very puzzle;you need configure the function call ‘s sample time in the runnable/system;i mean the display of f() . do not configure reference