Effacer les filtres
Effacer les filtres

Variant subystems with mixed discrete/continuous?

2 vues (au cours des 30 derniers jours)
Jason
Jason le 10 Août 2012
I am trying to use a variant subsystem to switch between a continuous block and a discrete block - a derivative block and a difference block, respectively. When the variant is set to the derivative block, the diagram will be used to run a simulation directly. When the variant is set to the difference block, the diagram will be used to generate code.
In principle, this should work, since only one variant is active at a time. When I generate code, I want the continuous variant to be left out completely, as it will be inactive. However, when I try to generate code, it complains that there are continuous states, so it can't (presumably because the derivative block is still there, even though it is inactive.) Is there some way that I can configure it to completely ignore non-active blocks, depending on how my variants are set?
  2 commentaires
Azzi Abdelmalek
Azzi Abdelmalek le 11 Août 2012
Modifié(e) : Azzi Abdelmalek le 11 Août 2012
what do you mean to generate code?
Jason
Jason le 16 Août 2012
I am referring to the Simulink coder... ctrl+B

Connectez-vous pour commenter.

Réponses (2)

TAB
TAB le 13 Août 2012
I think enabling Override variant conditions should work for you.
  1 commentaire
Jason
Jason le 16 Août 2012
That option, as I understand it, merely removes the Variant Conditions from the picture, and allows you to specify a variant directly. My Variant Conditions are operating properly, and it shows the correct one as "true" in the variant subsystem parameters, so there's no reason to use this option.

Connectez-vous pour commenter.


Guy Rouleau
Guy Rouleau le 13 Août 2012
I would be surprised if this is because of the derivative block. Usually, inactive variant should completely disappear.
- Ensure the option "Generate preprocessor conditional" is disabled. Otherwise both variants will be present... this is the only reason I know for 2 variants to be present.
- Use sample time colors or Simulink.BlockDiagram.getInitialState to identify which block has continuous state in your model.
  1 commentaire
Jason
Jason le 16 Août 2012
I have the "generate preprocessor conditionals" disabled, but it appears that when code is generated is still cares about the inactive variant. I don't know why.
Can you elaborate on the sample time colors? I don't understand what you are saying here.

Connectez-vous pour commenter.

Catégories

En savoir plus sur Component-Based Modeling dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by