Discrete Integrator inside Function-Call subsystem; unexpected resets?

1 vue (au cours des 30 derniers jours)
Greg
Greg le 6 Juin 2019
Hello,
I am trying to create a signal fault detection system in Simulink (Fixed Step Solver). I have simplified my model down to a single signal to help clarify the issue I am experiencing. The desired function of the system is this:
  1. Signal is fed into a function-call subsystem; the subsystem is driven by a function-call generator at sample time 0.01 (iterations: 1)
topLevel.PNG
2. The signal is then compared with a limit (constant), and the boolean result is connected to a Discrete-Time Integrator. The value of the integral (1 or 0 x time) is compared to another constant (time limit) and the boolean result of that indicates a fault (i.e. if the signal limit is continuously exceeded for a given number of seconds, a fault is detected).
2ndLevel.PNG
The integral reset is set as a falling edge, so when the signal drops below the limit it should reset. When I run the simulation, everything works as expected until the integral reaches a value of ~2.6, and then it resets? Also, if I limit the integral output to 2.2, it works?
results.PNG
I'm sure my issue is probably something simple; anybody see what I am missing?
Thanks,
Greg

Réponses (0)

Catégories

En savoir plus sur Schedule Model Components dans Help Center et File Exchange

Produits


Version

R2016b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by